TECHNICAL
SPECIFICATIONS
GENERAL
Do not
apply coatings if temperature is below 15°c
or over 3O°c. (Low Temp Grade 0-30°c) Do
not apply coating if rain is imminent. Not
recommended for below grade waterproofing
or where water pressure is from within the
wall.
PREPARATION
The surface
to be treated should be dry clean sound
and free from oil, grease, flaking paint
and laitence and other deleterious materials. Sound
paint may be overcoated. New concrete
should be minimum 28 days old before application
commences. All cracks or holes exceeding
2mm are to be repaired before application
commences.
APPLICATION
/ SPECIFICATION
Apply one
coat of the appropriate Westox Primer. Apply
by brush, roller or airless spray to the
prepared surface.
VERTICAL
SURFACES
Apply one
coat at the rate of 4m2 per litre and allow
to dry. Apply second coat at the rate of
4m2 per litre W.F. T. approximately 250
microns. Finished dry film thickness (D.F.
T.) should then be approximately 275 microns.
(Total D.F. T. should never be less than
250 microns).
HORIZONTAL
SURFACES
Apply first
coat to primed surface at the approximate
rate of 2m2 per litre and whilst still wet
roll out reinforcing mesh and embed, working
with a brush to ensure complete saturation
of fabric.
Allow minimum
8 hours before application of second coat
of membrane at the rate of 2m2 per litre
and allow 24 hours to dry. Apply third coat
of membrane at the rate of 2m2 per litre
at right angles to previous coats.
Thoroughly
check surface after 24 hours to ensure that
complete coverage has been attained and
no pinholing is evident. Surface will be
touch dry in 8 hours, and will accept foot
traffic after 48 hours. Will achieve full
cure within 7 days. Avoid water ponding
for first 3 days after application.
SAFETY
- Not classified as dangerous goods
Refer to
Westlegate Pty Limited Material Safety Data
Sheet for instructions.
CLEANUP
dean up
all equipment in fresh water immediately
after use.
|